           ASJ series Residual Current Action Relay

          1. 概述

          Overview

          在工業(yè)應(yīng)用中,剩余電流繼電器與外部剩余電流互感器結(jié)合使用以檢測(cè)和評(píng)估接地故障電流。它們也可以與保護(hù)裝置結(jié)合使用,以實(shí)現(xiàn)電路的斷開,從而實(shí)現(xiàn)對(duì)線路和人員的保護(hù)。

          Residual current relay can be combined with external residual current transformer to detect and evaluate the ground fault current. They can also be combined with protective devices to realize the disconnection of circuits and the protection of lines and workers.

          2.剩余電流的定義以及危害

          Definition and risk of residual current

          剩余電流,是指低壓配電線路中各相(含中性線)電流矢量和不為零的電流。通俗講當(dāng)用電側(cè)發(fā)生了事故,電流從帶電體通過(guò)人體流到大地,使主電路進(jìn)出線中的電流I相和I中的大小不相等,此時(shí)電流的瞬時(shí)矢量合成有效值稱為剩余電流,俗稱漏電。

          Residual current is the current vector sum of each phase (including the neutral ) in the low-voltage distribution that not be zero. Generally, when there is an accident on the power side, the current flows from the charged body to the earth through the human body,it will cause that the current phase I in the main circuit not equal to the size in phase I. At this time, the value of instantaneous current vector synthesis is called residual current, commonly known as leakage.

          TN System

          3.剩余電流的危害:

          Risk of residual current:

          人身觸電。當(dāng)電氣設(shè)備因絕緣損壞而使外殼帶電,而工作人員又接觸此外殼時(shí),就會(huì)導(dǎo)致人身觸電事故。

          (1)Physical electric shock. When shell of the electrical equipment is electrified due to insulation damage, and the workers touch the shell again, it will lead to physical electric shock accident.

          燒損電氣設(shè)備,引起火災(zāi)。長(zhǎng)期存在的漏電電流,尤其是兩相經(jīng)過(guò)電阻接地的漏電電流,在通過(guò)設(shè)備絕緣損壞處時(shí)將散發(fā)出大量的熱,使絕緣進(jìn)一步損壞,甚至使可燃性材料(如非阻燃性橡套電纜)著火燃燒。

          Burn electrical equipment and cause fire. The long-term leakage current, especially the leakage current of  two-phase grounded through resistance, will release a lot of heat when flow through the damaged part of the equipment insulation, further damaging the insulation, and even making combustible materials (such as non flame retardant rubber sheathed cable) burn on fire.

          引起短路事故。據(jù)統(tǒng)計(jì),約有30%的單相接地故障發(fā)展為短路。從而造成更大的電氣故障。長(zhǎng)期存在的漏電電流及電火花使漏電處的絕緣進(jìn)一步損壞,后危及相間絕緣而造成短路。

          (3) Cause short circuit accident. According to statistics, about 30% of single-phase grounded faults develop into short circuit which will give rise to heavier electrical failure. The long-term leakage current and spark further damage the insulation at the leakage point, and finally endanger the interphase insulation and cause short circuit.

          引起電氣火災(zāi)事故。電網(wǎng)發(fā)生單相接地或設(shè)備發(fā)生單相碰殼時(shí),在接地點(diǎn)就會(huì)產(chǎn)生電火花,若此電火花具有足夠的能量,就可能點(diǎn)燃易燃易爆物品。

          Cause electrical fire accident. When the single-phase grounding occurs in the power grid or the single-phase collision occurs in the equipment, the electric spark will be generated at the grounding point. If the electric spark has enough energy, it may ignite flammable and explosive materials.

          4.如何測(cè)剩余電流

          How to measure residual current

          在被測(cè)的三相導(dǎo)線路上與N線上各裝一個(gè)CT,或讓三相導(dǎo)線與N線一起穿過(guò)一個(gè)零序CT,得到三相導(dǎo)線與中性線N的電流矢量和IA*+IB*+IC*+IN*,當(dāng)沒有發(fā)生單相接地故障時(shí),無(wú)論三相負(fù)荷平衡與否,則此矢量和為零;當(dāng)發(fā)生某一相接地故障時(shí),故障電流中會(huì)通過(guò)保護(hù)PE及與地相關(guān)連的金屬構(gòu)件回到電源,即IA*+IB*+IC*+IN*,此時(shí)數(shù)值為接地故障電流Id。

          Installing a CT on each of the three-phase conducting lines to be tested and N line or let the three-phase conductor and the n-line pass through a zero sequence CT together to get the current vector sum IA * + IB * + IC * + IN * . when there is no single-phase grounded fault, whether the three-phase load is balanced or not, the vector sum is zero; when there is a phase grounded fault, the fault current will flow through the protection PE and the metal components connected to the earth to the power supply, at this time, the value is the ground fault current Id.

          5.ASJ系列剩余電流動(dòng)作繼電器

          ASJ series residual current operated relay

          ASJ系列剩余電流動(dòng)作繼電器可與低壓斷路器或低壓接觸器等組成組合式剩余電流保護(hù)裝置, 主要適用于交流 50Hz, 額定電壓 400V 及以下的 TT 和 TN 系統(tǒng)配電線路, 用來(lái)對(duì)電氣線路進(jìn)行接地故障保護(hù), 防止接地故障電流引起的設(shè)備損壞和電氣火災(zāi)事故, 也可用來(lái)對(duì)人身觸電危險(xiǎn)提供間接接觸保護(hù)。

          ASJ series residual current action relay can be combined with low voltage circuit breaker or low voltage contactor to form a combined residual current protection device.It is mainly used for TT and TN system distribution lines with AC 50Hz and rated voltage of 400V and below.It is used to protect the electrical circuit from ground faults, prevent equipment damage caused by ground fault current and electrical fire accidents, and can also be used to provide indirect contact protection against personal electric shock hazard

          參考文獻(xiàn) Bibliography

          1.Solutions For Enterprise Micro-grid System 2020.02

         


        蘇公網(wǎng)安備 32028102001319號(hào)

        主站蜘蛛池模板: 国产亚洲一区区二区在线| 亚洲综合国产一区二区三区| 国产精品综合一区二区三区| 亚洲中文字幕无码一区| 日韩免费一区二区三区在线| 久久亚洲中文字幕精品一区| 丰满爆乳无码一区二区三区| 中文字幕日韩一区| 东京热无码一区二区三区av| 国产激情一区二区三区在线观看| 久久精品国产第一区二区三区| 久久精品国产一区二区三区日韩| 小泽玛丽无码视频一区| 国产亚洲综合一区二区三区| 蜜桃传媒一区二区亚洲AV| 亚洲一区二区三区深夜天堂| 国模吧一区二区三区| 中文字幕在线观看一区二区三区| 制服美女视频一区| 国产精品99精品一区二区三区| 亚洲精品色播一区二区| 国产99久久精品一区二区| 亚洲国产视频一区| 一区高清大胆人体| 精品人妻一区二区三区浪潮在线| 少妇激情AV一区二区三区| 日韩精品一区二区亚洲AV观看| 日韩人妻精品一区二区三区视频| 久久精品一区二区三区四区| 波多野结衣中文字幕一区| 亚洲电影唐人社一区二区| 日本片免费观看一区二区| 亚洲av成人一区二区三区观看在线| 国产自产对白一区| 日本免费一区二区三区最新vr| 国产无吗一区二区三区在线欢 | 狠狠做深爱婷婷久久综合一区| 亚洲午夜一区二区三区| 怡红院一区二区三区| 国产福利电影一区二区三区,亚洲国模精品一区 | 亚洲高清偷拍一区二区三区|